Helium Leak Detection: The Cornerstone of Reliable Liquid Cooling Plates Amid AI-Driven Growth
As AI chip power consumption surges past the kilowatt mark, liquid cooling technology has evolved from an option to a necessity for high-density data centers and new energy vehicles, driving explosive growth in the liquid cooling plate market. With extensive experience in liquid cooling plate helium leak detection and a robust customer base across China’s leading new energy and data center industries, we recognize that rigorous leak testing is the linchpin of product reliability. This article explores the future trends of liquid ...
Learn More
> -
Successful Collaboration with CIPSA Group: Sniffing Method Helium Leak Detection and Recovery System
At Anhui Daxin Vacuum Technology Co., Ltd., we pride ourselves on delivering-edge helium leak detection equipment tailored for industrial applications. In September 2025, we partnered with Mexico's CIPSA Group to provide a customized sniffing method helium leak detection and recovery system for stainless steel pipe fittings, ensuring superior cutting airtightness and efficiency in their manufacturing process. This advanced system integrates multiple functions: high-pressure nitrogen/compressed air filling for gross leak detectio...
Learn More
> -
Pressure sensor industry
Leakage detection accuracy 1.0E-6~1.0E-5Pa.m3/s; Helium filling pressure 1.5~7.0MPa; Detection rhythm 7s~15s/piece; Detection method Check the overall leakage rate; Multi level leak detection detecting major and minor leaks Level 3 leakage detection major leakage detection, medium leakage detection, and minor leakage detection; Structural style bell type Security protection grating protection, electrical interlocking, hi...
Learn More
> -
Corrugated Pipe industry
Leakage detection accuracy 1.0E-6~1.0E-5Pa.m3/s; Helium filling pressure 0.05~0.3MPa; Detection rhythm 10min~20min/reel; Detection method Check the overall leakage rate; Level 3 leakage detection major leakage detection, medium leakage detection, and minor leakage detection; Structural style side door opening, etc Security protection grating protection, electrical interlocking, hierarchical password, sound and light alarm; E...
Learn More
> -
Fire extinguisher industry
Leakage detection accuracy 1.0E-7~1.0E-4Pa.m3/s; Helium filling pressure 1.0~3.0MPa; Detection rhythm 0.5min~3min/piece; Detection method Check the overall leakage rate, and can also assist in using the suction gun method to find leakage points; Level 3 leakage detection major leakage detection, medium leakage detection, and minor leakage detection; Structural style bell type/sliding door type/side door type, etc Security protection gr...
Learn More
> -
Hydrogen cylinder industry
Leakage detection accuracy 6NmL/(h·L), 1.0E-6~1.0E-3Pa.m3/s; Helium filling pressure 35.0~87.5MPa; Detection rhythm hydrogen cylinder: 15-60min/piece; Detection method Check the overall leakage rate, and can also assist in using the suction gun method to find leakage points; Structural style side door opening; Security protection grating protection, electrical interlocking, hierarchical password, sound and light alarm; Automation PLC c...
Learn More
> -
Water cooled panels industry
Leakage detection accuracy 1.0E-7~1.0E-4Pa.m3/s; Helium filling pressure 0.25~2.0MPa; Detection rhythm 20s~300s/piece; Detection method Check the overall leakage rate, and can also assist in using the suction gun method to find leakage points; Level 3 leakage detection major leakage detection, medium leakage detection, and minor leakage detection; Structural style bell type/sliding door type etc; Security protection grating protection, ...
Learn More
> -
High voltage GIS industry
Leakage detection accuracy SF6/NON-SF6 gas, 0.01%~0.5%/year Helium filling pressure 0~0.8MPa; Detection rhythm 10min~60min/piece; Detection method positive pressure suction method, manually holding a helium suction gun to detect leaks at the leakage point; Configuration selection helium recovery system+helium mass spectrometer leak detector; Security protection electrical interlocking, hierarchical password, sound and light alarm; Econo...
Learn More
> -
Power GIS switchgear industry
Leakage detection accuracy: SF6/NON-SF6 gas, 0.01%~0.5%/year; Helium filling pressure: 0~0.05MPa; Filling pressure of SF6/NON-SF6 0.1~0.15MPa; Detection rhythm: 15min~60min/piece; Detection method: Check the overall leakage rate and also assist in finding leakage points; Level 3 leakage detection: major leakage detection, medium leakage detection, and minor leakage detection; Structural style: automatic side door opening type; Security protection: grati...
Learn More
> -
Compressor industry
Leakage detection accuracy: refrigerant 1g/y~14g/y, i.e.5.0E-7~7.0E-6Pa.m3/s; Helium filling pressure: 0~2.5MPa; Detection rhythm: 30s~180s/piece; Detection method: Check the overall leakage rate and also assist in finding leakage points; Level 3 leakage detection: major leakage detection, medium leakage detection, and minor leakage detection; Structural style: Bell type/sliding door type; Security protection: grating protection, action interlocking, hierarchical passwo...
Learn More
>